![]() ![]() ![]() The multifunction LCD readout showcases real-time power/battery status at a single push-of-a-button. RJ11/RJ45 (One-in/One-out) port is included for the protection of phone and network line. This UPS system is designed with patented GreenPower UPS bypass circuitry that improves the operating efficiency so that users can enjoy significant cost savings by reducing energy consumption and waste heat generated. I’m no APC Guru but I’ve been using these UPS backups for decades and while not having many problems with them I have indeed experienced a few.The BRICs LCD BR1200ELCD UPS for home and small office computer systems and electronic devices features line conditioning and protection against surges/spikes, provides reliable battery backup and clean power supplies during brownouts or power failures. Therefore the battery is fine, but there is a failure in the self test or part of that may be the charging system that does not allow the unit to attempt to continue, be this by design I don’t know yet as I’m still researching.Ĭhances are internal hardware failure and requires replacement of the entire unit, one positive note, since the battery is probably still good you can swap it out and reserve the newer battery for later use. I’m personally thinking this is a self test issue where the unit does not detect a successful switch over to battery usage before it switches back to normal mode. All unit vitals look fine aside from showing 0% battery life when plugged in and hearing constant yet intermittent chirps from the APC unit. Checked circuit breaker on the unit and that of the power strip, all good. My mom is having similar trouble with her APC XS 1000 unit, battery is actually 3/4 full when unit is unplugged from the wall and still provides power to computer. Perhaps the original battery would still be okay if the UPS had kept it charged. I replaced the battery in the fall of 2019 because the original battery died. My hunch is that the battery is now never being charged and will eventually be permanently damaged. The software also reports the battery is fully charged, which is implausible since I know from experience that it takes hours to reach full charge after a selftest. After startup the UPS software reports the selftest was passed, but given the circumstances I don’t have confidence that that report is valid. To protect the battery from being drained so far that the battery is damaged, and to protect my pc from losing power and crashing, I respond by quickly shutting down the pc, then shut off and restart the UPS, and then restart the pc. However, recently the UPS developed a second problem that magnifies the first: During the selftest, the pc “loses communication” with the UPS (connected via usb port), the software doesn’t indicate the selftest has completed, and the UPS seems like it remains in battery mode… its internal fan doesn’t stop spinning, as if it isn’t cooling down and is continuing to drain the battery. I’ve been doing a selftest about once per month. So, for awhile it was possible to maintain a charge by periodically performing a UPS selftest. The reason I believe the UPS hasn’t been keeping the battery charged is that the selftest reduces the reported battery charge from 100% to about 65% in a few seconds, and then it takes hours of charging before the UPS software (CyberPower PowerPanel Personal v2.2.0) reports the battery is again at 100%. It seems the only time it will charge the battery is immediately after a selftest it charges the battery to full after a selftest but then it ridiculously thinks the battery stays fully charged while the battery actually gradually loses its charge (which will eventually destroy the battery if it’s allowed to discharge too far). I have a similar problem with my CyberPower UPS (model CP1000PFCLCD).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |